Export AASX and product passports from DS Studio

Open a sample flow in DS Studio PLAY, download a process AASX and a product passport, and inspect the files. Then reopen the process package to recover the model. You can follow the guide with the built-in examples.

Curriculum level: Introductory7 source sections
Open DS Studio PLAY (dualsoft.ai) →

What you get#

Choose AASX to exchange equipment control logic and its model source. Choose DPP to share product information. Both filenames end in .aasx. The product passport has the compound extension .dpp.aasx.

What you get · Item / Process AAS (.aasx)
ItemProcess AAS (.aasx)Product AAS (.dpp.aasx)
Used forProcess and equipment information for exchangeProduct-passport data; distinguish model samples from production records
ButtonAASXDPP
AAS granularityDepends on the systems declared in the modelThe sample without measurements produces a product type (Type) template
SubmodelsNameplate, SequenceControlData and model-dependent Models3D, AID or AIMC; inspect the outputNameplate, DppMetadata, HierarchicalStructures, ExecutedProcesses and TechnicalData
Equipment control dataIncludedNot included
Model source (model.ds2)Included, so the package can be re-importedNot included

Step 1: Open PLAY and prepare a model#

Select Open DS Studio PLAY above and choose Cartesian Robot Alignment on the start screen. The built-in example opens without a customer file or an account.

To use your own model, inspect Open Local File (.ds2/.aasx) on the start screen, or Import DSL Source… (.ds2, .dsdx) and Import AASX Package… (.aasx) in the Export menu.

To inspect a model with I/O addresses, open XG5000 Circulation Demo Kit. Export the process AASX to examine the controller and its equipment units.

  • Pick an example card on the start screen, or choose an example from the File menu when another flow is already open.
  • When analysis finishes, check the flow name in the header and the rendered flow.
  • An active system is the controller that directs the process sequence. A passive system is an equipment unit that acts on its requests.

Step 2: Check the model#

When a model opens, PLAY analyses the source automatically. The badge next to the flow name then reads Basic Check. There is no separate compile button. Basic Check reports the static result for the current source and does not mean that execution verification has passed.

For model execution checks, open the Verification tab. Inspect the results for the source you used. Physical commissioning requires separate evidence.

Both examples allowed the process and passport downloads after Basic Check. Inspect syntax and static diagnostics for the model you plan to export.

If a button is disabled, confirm that a model is open and that loading has finished. Resolve any reported errors and recheck the source. If the exported package carries DRAFT status, retain it as a working copy and export again after fixing the diagnostics.

Step 2: Check the model · State / AASX button
StateAASX buttonDPP and other deliverable buttons
Checked basic example at Basic CheckEnabled; download observedAvailable; passport downloaded
Other models, loading and error statesCheck the current versionCheck the current version

Step 3: Export the AASX package#

The file is delivered through the browser download mechanism. The browser may ask where to save it, depending on its settings.

Inspect AAS and submodel identifiers in the downloaded file. This recheck did not test identifier or byte equality across repeated exports or browsers.

The full list is available under Search All Deliverables & Advanced JSON Options… near the bottom of the menu. The observed download in this check used the AASX button on the main row.

Use the filename in the notification to locate the package in browser downloads. If controls are unavailable, wait for loading to finish and resolve any remaining model diagnostics.

  • Open the Export menu in the header.
  • Find the row IDTA AASX Package & Digital Product Passport.
  • Choose AASX on that row.
Step 3: Export the AASX package · Item / Value
ItemValue
File nameThe name shown in the notice (….aasx). For the built-in examples it matches the header name; a flow imported from a .ds2 file follows the imported file name.
Size and item countsPackage size and contents depend on the model, language and product version. Inspect the shells and submodels in the file you received.
FormatZIP-based AASX package, MIME type application/aas+zip
Sign-inNot required when checked
Course illustration: The AASX and DPP buttons appear side by side on the IDTA package row of the PLAY export menu. (opens in a new tab)
In PLAY, select AASX for the process package or DPP for the product passport.

Step 4: Look inside the .aasx#

An AASX uses relationship files (.rels) to link environment data and attachments. The checked basic export used aasx/data.json and had no XML environment file. Inspect both the ZIP listing and relationship targets for the model source (aasx/files/00_source/model.ds2), workspace state (ui-session.json), thumbnails and model-dependent 3D files.

Open the file with a ZIP reader and inspect assetAdministrationShells and submodels in aasx/data.json. The Cartesian example contained two shells, and the circulation demo contained thirteen. In the demo kit, AssetInterfacesDescription and AssetInterfacesMappingConfiguration describe the controller I/O.

SequenceControlData is the DualSoft control-sequence submodel. DualSoft and Nestfield are pursuing registration of the IDTA 02107 template. Its structure, concept definitions and identifiers may change during review. Check the semantic identifier recorded in the package you received.

Nameplate and other submodels may contain example or empty values. When an output includes AID, inspect placeholders such as the endpoint (opc.tcp://localhost:4840) and security setting (nosec). Review real values and security conditions before handover; the basic-example check does not establish AID output for every model.

Package structure and metamodel rules can be checked with a public tool such as IDTA aas-test-engines. Passing that check does not establish template conformance. Release 1.0.3 checks template rules only for Digital Nameplate 2.0 and Contact Information 1.0, so Nameplate 3.0, AID and AIMC must be compared against the template documents.

Before opening the package in another AAS tool, confirm that the tool reads JSON data files. Opening in other tools was not tested for this guide.

Step 4: Look inside the .aasx · Submodel / Specification
SubmodelSpecificationPresent inContent
NameplateIDTA 02006-3-0 Digital Nameplate 3.0Active systemsManufacturer, product name, address, order code, serial number, year of construction
SequenceControlDataDualSoft-defined template 1.0All systemsSystem name, products and variables, APIs, flows (works, links, calls and their physical I/O addresses), mutual exclusion, I/O port mapping, hash and file of the model source
AssetInterfacesDescription (AID)IDTA 02017-1-1Active systems, only when the model declares I/O addressesOne OPC UA interface and one property per signal
AssetInterfacesMappingConfiguration (AIMC)IDTA 02027-1-0Same as AIDMapping between AID signals and SequenceControlData I/O ports
Models3DIDTA 02026-1-0 Provision of 3D ModelsSystems with 3D model data; observed in the English basic exportAttached 3D file and related metadata; inspect the actual path

Step 5: Export a digital product passport (DPP)#

Reopen Export · I/O and select DPP from the same row. Download the .dpp.aasx file, open it as a ZIP archive and inspect assetKind in aasx/data.json. In the default example, it is Type. The table lists the submodels present in the exported example passports.

Without measurement data, one Type passport is created for each product declared in the model. Unlike the process AAS, it contains neither SequenceControlData nor the model source.

TEMPLATE-LOT and MODEL_TEMPLATE identify a sample generated without production measurements. Before issuing a passport, resolve the product identifier and match the manufacturer, product identity and production record to source evidence for the item.

A test scenario may produce a passport marked FIXTURE. Before issuing a production passport, verify that its evidence refers to the actual product or lot.

Step 5: Export a digital product passport (DPP) · Submodel / IDTA template
SubmodelIDTA templatesemanticId
Nameplate02006-3-0 Digital Nameplatehttps://admin-shell.io/idta/nameplate/3/0/Nameplate
DppMetadata02099-1 Digital Product Passport Part 1https://admin-shell.io/idta/cds/dppMetadata/1
HierarchicalStructures02011-1-1 Hierarchical Structures enabling Bills of Materialhttps://admin-shell.io/idta/HierarchicalStructures/1/1/Submodel
ExecutedProcesses02031-2 Process Parameters Instancehttps://admin-shell.io/idta/ExecutedProcesses/1/0
TechnicalData02003 Technical Data 2.00173-1#01-AHX837#002

Step 6: Re-import and check before use#

Open Export · I/O and select Import AASX Package… (.aasx) under File Import. Confirm the prompt to replace the current draft and choose the process .aasx you downloaded. Once the workspace reopens, inspect the recovered flow and the Basic Check state. The product passport omits the DS model source needed for this step.

The Cartesian and circulation examples were exported in both formats, and the process packages were imported back into PLAY. Keep a local copy of the process .aasx or DS source for later work.

Inspect AAS Repository Settings in the File menu for repository configuration. The connecting component and reachable addresses depend on execution mode, browser and network access, HTTPS, CORS and authentication. Opening the public website does not establish that every connection is made by its public server. This review did not test external or private-network repository connections.

  • Nameplate manufacturer, address, order code, product URI, serial number and year of construction replaced with real values
  • AID endpoint and security setting replaced with site values
  • Passport identification link and manufacturer replaced, with no TEMPLATE or FIXTURE marker left
  • The receiving tool reads JSON data files, and the structure was checked with a test tool
  • Verify Entire Flow was run, and real equipment behaviour was confirmed separately

Key points#

  • AASX produces a process package with one AAS per system; DPP produces a passport package with product AAS only.
  • Nameplate values, the AID endpoint and the passport identification link are placeholders. Replace them before handing the package over.
  • A passing test tool or a verified badge does not establish template conformance or real equipment behaviour. Confirm those separately.

Questions and answers#

Do I need to sign in?

In English and Korean PLAY, both built-in examples opened without signing in. The process AASX and product passport downloaded, and the process package opened again.

Which IDTA templates does the export follow?

See the tables above for the nameplate, I/O and passport submodels and their identifiers. DualSoft and Nestfield are pursuing registration of the IDTA 02107 SequenceControlData template, which may change as it is reviewed.

Is the package compatible with other AAS tools?

It is an AASX (ZIP) package in the IDTA Part 5 format, with all AAS data in one JSON file (aasx/data.json). Confirm that the other tool reads JSON data files before opening it. Opening in other tools was not tested for this guide.

Must verification pass before I can export?

For both tested examples, AASX and DPP were available after Basic Check. If a control is disabled, wait for loading to finish and resolve any syntax or static errors.

Can I import a PLC program and convert it to AAS here?

The import entries in the Export menu are Import AASX Package and Import DSL Source. PLC program import is not one of them.

Can I open an exported .aasx again?

Yes. Select Import AASX Package and choose the process .aasx containing the model source. The tested examples reopened, with the workspace showing the basic model check.