AASX asset & control reference for legacy PLC

This public AASX file contains an Asset Administration Shell for a belt conveyor, with its nameplate, PLC control sequence and 3D geometry. The format check and the BaSyx upload and retrieval test apply to this file.

New to these factory & AAS terms? Read the quick plant guide
AAS
Asset Administration Shell: a standardized digital folder linking a physical machine or part to its nameplate, sequence, and 3D data.
AASX
A portable ZIP-based package bundling AAS submodels with attachments like 3D GLB geometry and manuals.
Sequence
The exact step order, interlocks, and reset conditions connecting equipment tasks (e.g., clamp before weld).
SequenceControlData
DualSoft's custom AAS submodel capturing flows, works, and causal links—kept explicitly distinct from official IDTA templates.
Work
One controllable task unit (e.g., Load, Clamp, Inspect) with its own completion state, start/reset conditions, and actions.

Why Legacy PLC-to-AASX Uses Loader, Log, Logic & Gap Separation#

Deployed PLC code alone loses original planning context as field edits accumulate. DualSoft's brownfield concept cross-checks Loader (topology), Log (observed events), and Logic (rules), surfacing mismatches in a separate Gap Review Queue—the same honesty principle behind EMPTY_UNSET and NOT_RUN here.

Deployment & Collaboration

Scope asset management and control by role.#

Align equipment records, PLC control handover, and AAS repository verification by team.

COLLABORATION

System Integrators (SI)#

Work to scope
Define which PLC sequences and asset metadata map automatically and which need engineering review.
What to prepare
A non-confidential sequence sample, tag/field definitions, and client handover limits.
Agreed result
An agreed reference mapping table and a clear exception list for joint review.
COLLABORATION

AAS Platform Vendors#

Work to scope
Confirm schema expectations and API calls required by the receiving AAS repository.
What to prepare
Repository API/version (e.g. BaSyx Part 2 API), identifier scheme, and expected payloads.
Agreed result
An agreed payload boundary and a reproducible server verification plan.
COLLABORATION

Manufacturing Teams#

Work to scope
Distinguish equipment Type structure from mandatory per-machine Instance values.
What to prepare
Equipment boundary, required nameplate/serial fields, and target AAS server.
Agreed result
A documented empty-field gap list and acceptance checks before sharing customer files.

Verified Facts and Scope Boundaries#

  • Reference asset scope1

    A public generic belt-conveyor asset authored by DualSoft so any team can download and inspect the structure directly.

  • Included submodels3

    Bundles equipment identification (Nameplate), DualSoft sequence data (SequenceControlData), and 3D geometry metadata (Models3D) in one package.

  • Package format checkaas-test-engines 1.0.3 (application/aas+zip)

    The recorded check covers AASX package structure and AAS metamodel conformance.

  • AAS server verificationBaSyx API 3.0: upload / 135 ID lookups

    Separate automated runs verified upload and ID lookups on BaSyx 2.0.0-milestone-15. Full API conformity and physical commissioning remain separate.

  • PLC engineering-tool importVendor PLC IDE import not executed Not yet checked

    Importing a project directly into a specific PLC vendor's engineering IDE has not yet been tested.

  • Physical equipment commissioningPhysical commissioning outside this reference scope Not yet checked

    Physical factory wiring, commissioning, and safety acceptance are outside this software reference scope.

Reference evidence#

Reference scope: Partial reference checks

These records cover only the fixed reference package below. They do not certify full API conformity or physical commissioning, and empty nameplate values require customer equipment data.

Reference evidence · Check / target / Recorded status
Check / targetRecorded statusEvidence / boundary
Package format and metamodelCheck passedaas-test-engines 1.0.3 · application/aas+zip
NameplateRecorded check completeIDTA 02006-3-0-3_Template_Digital Nameplate.json
Models3DRecorded check completeIDTA 02026-1-0-3_Template_ProvisionOf3DModels.json
SequenceControlDataIDTA comparison excludedDualSoft-defined submodel template (not an IDTA template)

Execution boundaries#

Execution boundaries · Check / target / Recorded status
Check / targetRecorded statusEvidence / boundary
AAS package checkRecorded check complete
Template comparisonRecorded check complete
BaSyx Part 2 API upload / lookupRecorded check completeBaSyx API 3.0: upload / 135 ID lookups
Vendor PLC IDE importNot executedVendor PLC IDE import not executed Not yet checked
Physical shop-floor acceptanceNot executedPhysical commissioning outside this reference scope Not yet checked

Reference package#

Reference package · Field / Recorded value / note
FieldRecorded value / note
File size337,693 B (329.8 KiB)
SHA-256c17eed7cb73ad96e73a08cd963dd0d617ac669b038095fb538ff3c0275c63030
LicenseCC0-1.0 AND MIT

Anonymous reproduction release: b01-aasx-repro-v1.zip (24,884 B · SHA-256 04cf9b6c9d929287…) — stdlib OPC XML, empty-value & negative checks without login (no third-party templates bundled; audit report, not certification).

Proof & Trust Center and 3D AAS 3-step tour#

Explore the public conveyor sample and Korean patents, or open the M200 station in the 3D viewer to follow its control sequence.

Scope and Verification FAQ#

Has this reference package been tested in Eclipse BaSyx Part 2 API?

BaSyx API 3.0: upload / 135 ID lookups. The recorded check used one fixed runtime and sample with separate automated reproduction. Attachment HTTP download, re-export, full API conformity and physical acceptance remain outside that result.

Does format checking cover vendor PLC IDE import or shop-floor commissioning?

Vendor PLC IDE import not executed Not yet checked, and Physical commissioning outside this reference scope Not yet checked. Customer-specific IDE and physical tests require explicit joint scoping.

Is SequenceControlData 1/0 an official IDTA Submodel Template?

No. SequenceControlData 1/0 is a DualSoft-defined namespace with English ConceptDescriptions and is excluded from IDTA template conformance comparisons.

Why are some Nameplate fields empty (EMPTY_UNSET) in the reference package?

Because this public package models a generic equipment Type rather than a private customer machine, instance-specific values such as site addresses or serial numbers are intentionally left unset. In a real project, mandatory fields are mapped from your source records and checked against your acceptance criteria.

What happens after you email us#

  1. Review source formats, control targets, and target AAS environment
  2. Map required, missing, and control-exception fields against our reference
  3. Agree on secure channels, deliverables, and commissioning checks first
Content reviewed Prepared by: DualSoft · website content

Scope and deliverables are agreed together before any customer data is handled.

Reference package#

b01-01-belt-conveyor.aasx

Ctrl+C: Copy selected code

Back to top

opens in a new tab