What is an Asset Administration Shell (AAS)?

An Asset Administration Shell (AAS) is a standard way to represent an asset so different applications can exchange its information. IEC 63278-1 defines the shell’s structure. IDTA’s metamodel describes its building blocks, including submodels that group information about one aspect of the asset.

Curriculum level: Introductory6 source sections
Explore a conveyor example

What does an AAS contain for one conveyor?#

Open DualSoft’s conveyor AASX file, a package that contains the model and its attachments. Nameplate holds the equipment identification fields. SequenceControlData is DualSoft’s reference submodel for operating steps. Models3D points to the 3D geometry bundled with the file.

Download the conveyor AASX

The published checks cover the file format, the AAS model structure and upload and retrieval on a test server. For your own equipment, start by identifying which data you want to exchange.

See the package checks PLC AAS integration guide Discuss an AAS project

What an AAS is#

IEC 63278-1:2023 defines the AAS as the structure of a standardized digital representation of an asset. Its purpose is to let two or more software applications exchange information. IDTA Part 1 (IDTA-01001) specifies this structure as a technology-neutral UML metamodel, which is the basis for the XML, JSON and RDF serializations.

An asset is anything of value to an organization: equipment, components and products, but also intangible assets such as software, documents and processes. One AAS represents exactly one asset.

The building blocks#

The main classes of the Part 1 metamodel.

  • AASd-131: AssetInformation must have a globalAssetId or at least one specificAssetId.
  • globalAssetId is optional (0..1) because early in the life cycle there may be none, but it is required as soon as the AAS is exchanged with partners.
  • specificAssetIds (serial number, customer part ID ...) need not be globally unique; they mainly support discovery of shells.
The building blocks · Class / Role
ClassRoleIdentified byKey attributes
AssetAdministrationShellThe shell for one assetid (mandatory Identifier)assetInformation (1), submodels (0..*), derivedFrom (0..1)
AssetInformationIdentifying metadata of the assetNo own id; part of the shellassetKind (1), globalAssetId, specificAssetIds, assetType, defaultThumbnail
SubmodelOne aspect of the asset (nameplate, technical data, documents ...)id (mandatory)kind, semanticId (recommended), submodelElements
SubmodelElementData and functions inside a submodelidShort (unique in its namespace)Property, SubmodelElementList and 12 other concrete types
ConceptDescriptionDefinition of meaning (dictionary entry)id (mandatory)isCaseOf, IEC 61360 data specification
EnvironmentContainer for serialization and file exchangeNot a ReferableassetAdministrationShells, submodels, conceptDescriptions

Submodels sit next to the shell, not inside it#

In the metamodel the AAS does not contain its submodels. It points to them with ModelReferences, and each Submodel is an independent object with its own id. In JSON, identifiables (AAS, Submodel, ConceptDescription) appear only in the top-level arrays of the Environment.

Below is a minimal v3 JSON example. modelType tells the parser which class an object is, and empty arrays are not written (an empty 0..* attribute is omitted). Most mandatory Digital Nameplate elements are left out to keep the structure visible.

Copy the code, or select it to copy manually.

JSON
{
  "assetAdministrationShells": [
    {
      "modelType": "AssetAdministrationShell",
      "id": "https://example.com/ids/aas/pump-0001",
      "idShort": "Pump0001",
      "assetInformation": {
        "assetKind": "Instance",
        "globalAssetId": "https://example.com/ids/asset/pump-0001",
        "specificAssetIds": [ { "name": "SerialNumber", "value": "P-0001" } ]
      },
      "submodels": [
        { "type": "ModelReference",
          "keys": [ { "type": "Submodel", "value": "https://example.com/ids/sm/pump-0001-nameplate" } ] }
      ]
    }
  ],
  "submodels": [
    {
      "modelType": "Submodel",
      "id": "https://example.com/ids/sm/pump-0001-nameplate",
      "idShort": "Nameplate",
      "kind": "Instance",
      "semanticId": { "type": "ExternalReference",
        "keys": [ { "type": "GlobalReference", "value": "https://admin-shell.io/idta/nameplate/3/0/Nameplate" } ] },
      "submodelElements": [
        {
          "modelType": "Property",
          "idShort": "SerialNumber",
          "semanticId": { "type": "ExternalReference",
            "keys": [ { "type": "GlobalReference", "value": "0112/2///61987#ABA951#009" } ] },
          "valueType": "xs:string",
          "value": "P-0001"
        }
      ]
    }
  ]
}

Adding meaning: semanticId and ConceptDescription#

The meaning of a SubmodelElement comes from its semanticId. It can point directly to an external dictionary entry such as ECLASS or IEC CDD, or to a ConceptDescription in the Environment. In the example, 0112/2///61987#ABA951#009 is the IEC CDD identifier that the Digital Nameplate template uses for SerialNumber.

A ConceptDescription typically carries the IEC 61360 data specification (Part 3a) with attributes such as preferredName, definition, unit and dataType. If it is a copy of an external definition, it may reuse the same id or point to the original via isCaseOf.

Map of the specification documents#

The AAS specification is split into parts. Part 1 v3.2 is aligned with the versions below (IDTA releases as of November 2026).

  • IEC 63278-1:2023 (December 2023) standardizes the AAS structure internationally. Part 1 takes its terms and definitions from IEC 63278-1:2023 where available.
  • Part 1 is the common basis for three ways of exchange: API (Part 2 Repository, Registry and Discovery), file serialization (Part 5 AASX) and the I4.0 language.
Map of the specification documents · Document / Number
DocumentNumberScopeCurrent version
Part 1 MetamodelIDTA-01001Classes, attributes, constraints; XML/JSON/RDF mappingsv3.2 (July 2026)
Part 2 APIIDTA-01002HTTP/REST API, service specifications and profiles, queryv3.2
Part 3aIDTA-01003-aData specification based on IEC 61360v3.1.1
Part 3bIDTA-01003-bData specification for units of measurementv3.0
Part 4 SecurityIDTA-01004Access rule model (ABAC), security requirementsv3.1
Part 5 AASXIDTA-01005Package file format based on Open Packaging Conventionsv3.2

Why it matters for manufacturing engineers#

  • The same structure holds type data (data sheets) and instance data (serial number, operating data). Keeping the type-instance relationship lets you forward updates from the type to its instances.
  • IDTA submodel templates come with predefined semanticIds, so creating an instance means creating the elements and filling in values.
  • Information that no standard covers can go into your own submodels. The specification asks systems to ignore submodels and properties they do not know, so standard and proprietary data travel over one infrastructure.
  • The same model can be served live over Part 2 Repository and Discovery APIs for plant repositories and supply-chain data spaces, or serialized into an AASX package when offline handover is needed.

Key points#

  • One AAS represents one asset. The shell id and the asset's globalAssetId are different identifiers.
  • The shell points to submodels via ModelReferences; live operations use Part 2 Repository and Discovery APIs, while offline serializations place identifiables side by side in the Environment.
  • Part 1 (metamodel) is the core; Parts 2 (API), 3a, 3b, 4 (security) and 5 (AASX) are versioned alongside it. Agree on versions with your partner first.

Questions and answers#

Can the AAS id and the globalAssetId be the same value?

They identify different things: id identifies the shell, globalAssetId identifies the asset. The Part 1 annex example also uses different values for the shell (http://T1.com) and the asset (0215551AAA_T1). Keeping them separate avoids confusion.

Do I have to include ConceptDescriptions?

No. conceptDescriptions in the Environment is 0..*, and a semanticId may point straight to an external dictionary. Without a ConceptDescription or data specification, however, attributes such as preferredName or unit are not available offline and must be looked up elsewhere.

Which version should I build against?

The current release is Part 1 v3.2. XML namespaces differ per version (https://admin-shell.io/aas/3/0, /3/1, /3/2) and newer enum values such as Role or Batch do not exist in older schemas, so match the version that the receiving tool or server supports.

Is an AAS the same thing as an AASX?

No. The AAS is the model; AASX is the package file format from Part 5. It bundles the serialized AAS (XML or JSON) with supplementary files referenced by File elements. Part 5 v3.2 uses the MIME type application/aas+zip.

Content updated Source date not recorded

Ctrl+C: Copy selected code

Back to top