From DS2 single-source model to PLC execution, GRAFCET drawings, and field feedback

Keeping sequence drawings, PLC programs, 3D simulations, HMI screens, and AAS asset records synchronized manually breaks down as soon as a line changes. This architecture guide explains how DualSoft derives engineering deliverables from one sealed DS2 model revision, aligns with GRAFCET and IEC 61131-3 standards, and separates simulation evidence from hardware commissioning.

On this page

DS Pilot · DS Studio · Learning Hub

One sealed model revision, clear data lineage#

In the DualSoft architecture, engineers and AI tools author human-readable DS2 text, from which the compiler generates a read-only sealed Structured Data Format (SDF) revision and Control IR. Crucially, PLC IR parsed from legacy shop-floor controllers stays distinct from Control IR lowered from the authored SDF, so reverse-engineered evidence and forward-generated control logic never overwrite each other silently.

Virtual-to-Real progression and Real-to-Virtual feedback#

Every execution configuration adds concrete physical constraints without discarding prior model invariants. Model-in-the-loop (MILS) validates sequence ordering and preconditions, software-in-the-loop (DS-SILS and PLC-SILS) adds actuator timing, scan periods, and controller types, hardware-in-the-loop (HILS) introduces real CPU firmware and communication latency against a virtual plant, and live operation (REAL) binds physical I/O. Read-only field logs flow back through DS Pilot so observed deviations inform the next reviewed SDF revision.

GRAFCET and control standard interoperability#

While GRAFCET remains the international standard for unambiguous sequential design intent, surrounding implementation and exchange standards continue to evolve across IEC 61131-3 Structured Text, PLCopen XML, OPC UA, and AutomationML Logic. DualSoft treats DS2 as a deterministic specification layer that emits clean GRAFCET sheets alongside IEC 61131-3 code, wiring drawings, and IDTA AASX packages from the same source hash.

Invariant evidence matrix and commissioning boundaries#

Each verification mode proves only what its execution boundary actually covers. Static compilation, offline timing diagrams, and simulation checks do not claim vendor PLC IDE import approval, safety integrity certification, or physical plant sign-off; whenever controller code, hardware topology, or field I/O changes, the affected evidence is re-verified explicitly.

Execution Configurations: MILS → SILS → HILS → REAL#

Information and verification evidence added across each execution mode
ConfigurationController / PlantInformation AddedVerification Boundary
MILSDS2 model logic executionSequence order, preconditions, initial state, logical timeCausal order, deadlock & interlock checks (no PLC)
DS-SILSDS scan kernel / virtual plantActive/Passive systems, kinematics, actuator timing, scan dtScan-quantized CT, timing & 3D/HMI verification
PLC-SILSPLC emulator / virtual plantPLC code, addresses, data types, scan policyGenerated ST/Ladder & PLCopen XML equivalence
HILSPhysical PLC / virtual plantCPU firmware, loaded image, comms/I/O latency, recoveryReal controller timing & I/O bus check (virtual plant)
REALPhysical PLC / live equipmentField I/O, safety interlocks, production logs, observed CTProject-scoped site commissioning & acceptance

Note: each configuration validates only its own boundary; static exports never substitute for vendor IDE import or physical commissioning.

GRAFCET (IEC 60848) & Control Standards Mapping#

Standards aligned with deterministic DS2 single-source generation
Standard DomainSpecificationRole in DS2 Architecture
Sequential Design IntentIEC 60848 · KS C IEC 60848Unambiguous step, action, transition, and operating-mode sheets
PLC Control ProgramsIEC 61131-3 · PLCopen XMLControl IR to 5-zone ST, Ladder, and vendor package export
Electrical & CAD ExchangeISO 7200 · IEC 62714 (AML)Title-block CAD drawings, I/O BOM, and AutomationML exchange
Industrial Information ModelIEC 62541 (OPC UA NodeSet2)Automated equipment object, status, and alarm NodeSet XML
Asset Shell & PassportIEC 63278-1 · IDTA Part 5 (AASX)Nameplate, SequenceControlData, and DPP exchange packages

Related Technical Notes#

Browse 18 DS Studio deliverable previews Read PLC log & unsupervised AI whitepaper

Verified by: DualSoft Engineering — DS2 Control Architecture & GRAFCET Standards Note