Eclipse BaSyx AAS server REST API verification: reproducible IEC 63278-1 checks

Building an Asset Administration Shell (AAS) file locally does not prove that an external IEC 63278-1 repository server can serve its shells, submodels, and identifiers cleanly over HTTP. This engineering guide walks through uploading a real PLC-derived AASX package to Eclipse BaSyx, encoding unpadded Base64URL keys, and verifying every submodel and concept ID through reproducible REST API probes.

Included visual & real-data evidence:Diagrams · 3Real Captures · 1Real Exports · 1Real Data · 1Tables · 4
On this page

DS Pilot · DS Studio · Learning Hub

How Eclipse BaSyx serves IEC 63278-1 shells and Base64URL identifiers#

Eclipse BaSyx implements the IDTA AAS Part 2 HTTP/REST specification (aligned with IDTA AAS Specifications v3.2 (IDTA-01001 / IDTA-01002)) so external MES, ERP, and AI systems can query standardized asset shells without vendor lock-in. Because AAS identifiers are full URIs or IRDIs containing slashes and colons, every REST path lookup must encode the identifier using unpadded Base64URL—replacing plus with hyphen, slash with underscore, and stripping trailing equals signs—before requesting /shells/{aasId} or /submodels/{submodelId}.

Editorial Diagram · Standard AASX Package, Base64URL Keys & Eclipse BaSyx REST API LookupDiagram
AASX upload, unpadded Base64URL encoding, and REST API submodel lookup on Eclipse BaSyxA layered AASX asset container flows via unpadded Base64URL identifier encoding into a modular AAS repository server, where REST API lookups verify the synchronized submodel hierarchy.
Reproducible BaSyx Part 2 REST Lookup Using Unpadded Base64URLIDTA AAS Part 2 REST API contract (b01-aasx-repro-v1 workflow)
# 1. Encode identifier URI as unpadded Base64URL (+ -> -, / -> _, strip =)
#    https://dualsoft.com/smt/SequenceControlData/1/0
# -> aHR0cHM6Ly9kdWFsc29mdC5jb20vc210L1NlcXVlbmNlQ29udHJvbERhdGEvMS8w

# 2. Query shells, submodels, and concept descriptions on your BaSyx server
curl -sS "${BASYX_URL}/shells"
curl -sS "${BASYX_URL}/submodels"
curl -sS "${BASYX_URL}/concept-descriptions/aHR0cHM6Ly9kdWFsc29mdC5jb20vc210L1NlcXVlbmNlQ29udHJvbERhdGEvMS8w"
Core IDTA AAS Part 2 REST API endpoints checked during Eclipse BaSyx interoperability verification
REST Endpoint PatternIdentifier EncodingWhat It VerifiesCommon Failure Mode
GET /shellsNone (collection query)Shell registration and globalAssetId presenceCorrupted AASX XML/JSON fails upload ingestion
GET /shells/{aasId}Unpadded Base64URLExact shell lookup and submodel reference linksStandard Base64 (+, /, =) causes client error responses
GET /submodels/{smId}Unpadded Base64URLFull submodel elements and semanticId preservationMissing semanticId or invalid element valueType
GET /concept-descriptions/{cdId}Unpadded Base64URLAll SequenceControlData concept definitions resolveBroken ConceptDescription references or duplicate IDs

Verifying submodels, semantic IDs, and SequenceControlData on the reference conveyor package#

DualSoft publishes a concrete reference belt-conveyor package bundling 3 submodels, 83 SequenceControlData concepts, and 84 canonical identifier URIs. Running aas-test-engines 1.0.3 (application/aas+zip) checks package structure and schema compliance offline, while BaSyx API 3.0: upload / 135 ID lookups confirms that every shell, submodel, and concept description resolves over live HTTP requests without silent truncation.

Editorial Diagram · Multi-Submodel (Nameplate, Technical Data, Sequence) Direct ID Round-TripDiagram
Nameplate, technical data, and sequence submodel IDs pass direct round-trip verificationEvery identifier across Digital Nameplate, Technical Data, and SequenceControlData submodels passes a direct verification matrix confirming lossless alignment between equipment twin and AAS server.
Real Export Output · DS Studio IDTA Standard AASX & SequenceControlData PackageReal Export Output
Actual DS Studio IDTA-compliant AASX export combining Digital Nameplate and SequenceControlDataDeterministic AASX package deliverable bundling nameplate metadata, technical properties, and sequence control structure verified against aas-test-engines and Eclipse BaSyx.
Reproducible verification layers applied to the public belt-conveyor reference AASX package
Verification StageTool / Server BaselineVerified ScopePublic Reproducibility
Package & Metamodel Schemaaas-test-engines 1.0.3 (application/aas+zip)AASX container, OPC relationships, AAS JSON/XML rulesDownloadable sample .aasx + reproduction bundle
Server Upload & ID LookupBaSyx API 3.0: upload / 135 ID lookupsShells, 3 submodels, and 83 concept IDsAutomated HTTP lookup script against local BaSyx
Canonical URI Resolutionhttps://dualsoft.com/smt/SequenceControlData/1/0/84 live documented concept URIsPublic HTTP 200 identifier specification page
Base64URL Encoding Auditunpadded Base64URLZero padding (=) or unsafe URL characters in pathsBrowser-side verifier on /guides/aas/base64url/

Separating verified BaSyx API checks from live plant commissioning#

Responsible IEC 63278-1 engineering states clearly what an Eclipse BaSyx REST API test proves—and what it does not prove. Passing offline schema validation and local BaSyx upload verifies data interoperability and identifier fidelity, whereas target vendor PLC IDE import (Vendor PLC IDE import not executed Not yet checked) and physical shop-floor acceptance (Physical commissioning outside this reference scope Not yet checked) remain separate project-scoped milestones owned by plant and control engineers.

Editorial Diagram · Verified Offline AAS Server Checks vs Staged Plant Commissioning BoundaryDiagram
Automated BaSyx API verification remains clearly separated from staged physical plant acceptanceReproducible offline AASX and BaSyx REST API checks on the left remain explicitly separated from staged plant commissioning and vendor IDE acceptance on the right.
Real Hardware Photo · DualSoft Physical Test Belt Conveyor HardwareReal Hardware Photo
Photograph of DualSoft physical test belt conveyor cell used to illustrate the boundary between offline AAS server verification and physical commissioning
Physical hardware integration stays explicitly separated from offline BaSyx server verificationPhotograph of DualSoft's test belt conveyor cell illustrating the physical equipment domain whose live plant commissioning remains separate from offline AASX server checks.
Truth boundary separating automated Eclipse BaSyx checks from factory-floor acceptance
MilestoneStatus in Public EvidenceWhat Passing ProvesWhat It Does Not Prove
AASX Format & Schema Checkaas-test-engines 1.0.3 (application/aas+zip)Valid IDTA AASX container and metamodel rulesDoes not prove live PLC communication
Eclipse BaSyx Part 2 LookupBaSyx API 3.0: upload / 135 ID lookupsClean server ingestion and Base64URL REST retrievalDoes not replace customer IT security or HA sizing
Vendor PLC IDE ImportVendor PLC IDE import not executed Not yet checkedVerified per customer controller toolchainNot claimed globally across untested firmware
Physical Shop-Floor FAT/SATPhysical commissioning outside this reference scope Not yet checkedVerified live I/O, safety interlocks, and cycle rateNever substituted by offline API or twin checks

Checklist: End-to-End Eclipse BaSyx & IEC 63278-1 AASX Interoperability Audit#

Practical engineering checklist before promoting an AASX package from local authoring to shared BaSyx repository deployment
Audit StepRequired InputExpected Verification ResultDualSoft Reference Resource
Offline Metamodel ValidationExported .aasx packageZero schema errors under aas-test-engines/guides/aas/aasx-create-validate/
Identifier Base64URL EncodingShell, submodel, and concept URIsUnpadded RFC 4648 URL-safe strings with no '='/guides/aas/base64url/
BaSyx Repository IngestionContainerized BaSyx Part 2 serverHTTP 200 on all shell, submodel, and concept lookups/guides/aas/aas-server/
Legacy PLC Sequence TraceabilitySequenceControlData submodelAll documented sequence concepts resolve cleanly/smt/SequenceControlData/1/0/
Plant Commissioning ScopeProject I/O map & safety planExplicit separation of server checks vs site FAT/SAT/solutions/aas-scope-checklist/

Verified Facts and Scope Boundaries#

  • Referenced AAS specificationIDTA AAS Specifications v3.2 (IDTA-01001 / IDTA-01002)

    The published IDTA AAS specification referenced across our migration and DPP notes.

  • Included submodels3

    Bundles equipment identification (Nameplate), DualSoft sequence data (SequenceControlData), and 3D geometry metadata (Models3D) in one package.

  • Documented concepts83

    Public English definitions document every custom sequence concept and ownership qualifier in the reference package.

  • Reference identifiers84

    Company-maintained public URIs identify the package's concepts, ownership qualifier, and submodel template.

  • Package format checkaas-test-engines 1.0.3 (application/aas+zip)

    The recorded check covers AASX package structure and AAS metamodel conformance.

  • AAS server verificationBaSyx API 3.0: upload / 135 ID lookups

    Separate automated runs verified upload and ID lookups on BaSyx 2.0.0-milestone-15. Full API conformity and physical commissioning remain separate.

  • PLC engineering-tool importVendor PLC IDE import not executed Not yet checked

    Importing a project directly into a specific PLC vendor's engineering IDE has not yet been tested.

  • Physical equipment commissioningPhysical commissioning outside this reference scope Not yet checked

    Physical factory wiring, commissioning, and safety acceptance are outside this software reference scope.

Scope and Verification FAQ#

Why do Eclipse BaSyx REST API lookups fail with client error responses even when the AASX upload succeeded?

The most frequent cause is using standard Base64 instead of unpadded Base64URL for shell, submodel, or concept-description IDs. Standard Base64 characters (+, /, and trailing =) break REST path segments unless converted to URL-safe unpadded Base64URL.

Can teams reproduce DualSoft's Eclipse BaSyx AASX verification independently?

Yes. DualSoft publishes the reference belt-conveyor .aasx file, the SequenceControlData 1/0 identifier specification, and a reproducible verification script bundle so engineering teams can run schema and local BaSyx REST lookup checks themselves.

How does DualSoft complement open-source Eclipse BaSyx instead of replacing it?

Eclipse BaSyx provides an open-source IEC 63278-1 AAS server and middleware ecosystem. DualSoft complements BaSyx by authoring and validating PLC-linked control models, generating standard AASX packages with SequenceControlData, and connecting equipment diagnostics without locking data inside a proprietary format.

Does passing an Eclipse BaSyx REST API check prove that a live factory PLC is already commissioned?

No. Passing aas-test-engines and BaSyx HTTP lookup checks confirms standard package structure and API interoperability. Vendor PLC IDE import, OT network policies, and physical shop-floor acceptance remain separate project-scoped milestones.

Verified by: DualSoft Engineering — Eclipse BaSyx & IEC 63278-1 REST API Verification Briefing

Content reviewed Prepared by: DualSoft · website content

Scope and deliverables are agreed together before any customer data is handled.

Back to top

opens in a new tab