Eclipse BaSyx AAS server REST API verification: reproducible IEC 63278-1 checks
Building an Asset Administration Shell (AAS) file locally does not prove that an external IEC 63278-1 repository server can serve its shells, submodels, and identifiers cleanly over HTTP. This engineering guide walks through uploading a real PLC-derived AASX package to Eclipse BaSyx, encoding unpadded Base64URL keys, and verifying every submodel and concept ID through reproducible REST API probes.
On this page
How Eclipse BaSyx serves IEC 63278-1 shells and Base64URL identifiers#
Eclipse BaSyx implements the IDTA AAS Part 2 HTTP/REST specification (aligned with IDTA AAS Specifications v3.2 (IDTA-01001 / IDTA-01002)) so external MES, ERP, and AI systems can query standardized asset shells without vendor lock-in. Because AAS identifiers are full URIs or IRDIs containing slashes and colons, every REST path lookup must encode the identifier using unpadded Base64URL—replacing plus with hyphen, slash with underscore, and stripping trailing equals signs—before requesting /shells/{aasId} or /submodels/{submodelId}.
# 1. Encode identifier URI as unpadded Base64URL (+ -> -, / -> _, strip =)
# https://dualsoft.com/smt/SequenceControlData/1/0
# -> aHR0cHM6Ly9kdWFsc29mdC5jb20vc210L1NlcXVlbmNlQ29udHJvbERhdGEvMS8w
# 2. Query shells, submodels, and concept descriptions on your BaSyx server
curl -sS "${BASYX_URL}/shells"
curl -sS "${BASYX_URL}/submodels"
curl -sS "${BASYX_URL}/concept-descriptions/aHR0cHM6Ly9kdWFsc29mdC5jb20vc210L1NlcXVlbmNlQ29udHJvbERhdGEvMS8w"| REST Endpoint Pattern | Identifier Encoding | What It Verifies | Common Failure Mode |
|---|---|---|---|
| GET /shells | None (collection query) | Shell registration and globalAssetId presence | Corrupted AASX XML/JSON fails upload ingestion |
| GET /shells/{aasId} | Unpadded Base64URL | Exact shell lookup and submodel reference links | Standard Base64 (+, /, =) causes client error responses |
| GET /submodels/{smId} | Unpadded Base64URL | Full submodel elements and semanticId preservation | Missing semanticId or invalid element valueType |
| GET /concept-descriptions/{cdId} | Unpadded Base64URL | All SequenceControlData concept definitions resolve | Broken ConceptDescription references or duplicate IDs |
Verifying submodels, semantic IDs, and SequenceControlData on the reference conveyor package#
DualSoft publishes a concrete reference belt-conveyor package bundling 3 submodels, 83 SequenceControlData concepts, and 84 canonical identifier URIs. Running aas-test-engines 1.0.3 (application/aas+zip) checks package structure and schema compliance offline, while BaSyx API 3.0: upload / 135 ID lookups confirms that every shell, submodel, and concept description resolves over live HTTP requests without silent truncation.
| Verification Stage | Tool / Server Baseline | Verified Scope | Public Reproducibility |
|---|---|---|---|
| Package & Metamodel Schema | aas-test-engines 1.0.3 (application/aas+zip) | AASX container, OPC relationships, AAS JSON/XML rules | Downloadable sample .aasx + reproduction bundle |
| Server Upload & ID Lookup | BaSyx API 3.0: upload / 135 ID lookups | Shells, 3 submodels, and 83 concept IDs | Automated HTTP lookup script against local BaSyx |
| Canonical URI Resolution | https://dualsoft.com/smt/SequenceControlData/1/0/ | 84 live documented concept URIs | Public HTTP 200 identifier specification page |
| Base64URL Encoding Audit | unpadded Base64URL | Zero padding (=) or unsafe URL characters in paths | Browser-side verifier on /guides/aas/base64url/ |
Separating verified BaSyx API checks from live plant commissioning#
Responsible IEC 63278-1 engineering states clearly what an Eclipse BaSyx REST API test proves—and what it does not prove. Passing offline schema validation and local BaSyx upload verifies data interoperability and identifier fidelity, whereas target vendor PLC IDE import (Vendor PLC IDE import not executed Not yet checked) and physical shop-floor acceptance (Physical commissioning outside this reference scope Not yet checked) remain separate project-scoped milestones owned by plant and control engineers.

| Milestone | Status in Public Evidence | What Passing Proves | What It Does Not Prove |
|---|---|---|---|
| AASX Format & Schema Check | aas-test-engines 1.0.3 (application/aas+zip) | Valid IDTA AASX container and metamodel rules | Does not prove live PLC communication |
| Eclipse BaSyx Part 2 Lookup | BaSyx API 3.0: upload / 135 ID lookups | Clean server ingestion and Base64URL REST retrieval | Does not replace customer IT security or HA sizing |
| Vendor PLC IDE Import | Vendor PLC IDE import not executed Not yet checked | Verified per customer controller toolchain | Not claimed globally across untested firmware |
| Physical Shop-Floor FAT/SAT | Physical commissioning outside this reference scope Not yet checked | Verified live I/O, safety interlocks, and cycle rate | Never substituted by offline API or twin checks |
Checklist: End-to-End Eclipse BaSyx & IEC 63278-1 AASX Interoperability Audit#
| Audit Step | Required Input | Expected Verification Result | DualSoft Reference Resource |
|---|---|---|---|
| Offline Metamodel Validation | Exported .aasx package | Zero schema errors under aas-test-engines | /guides/aas/aasx-create-validate/ |
| Identifier Base64URL Encoding | Shell, submodel, and concept URIs | Unpadded RFC 4648 URL-safe strings with no '=' | /guides/aas/base64url/ |
| BaSyx Repository Ingestion | Containerized BaSyx Part 2 server | HTTP 200 on all shell, submodel, and concept lookups | /guides/aas/aas-server/ |
| Legacy PLC Sequence Traceability | SequenceControlData submodel | All documented sequence concepts resolve cleanly | /smt/SequenceControlData/1/0/ |
| Plant Commissioning Scope | Project I/O map & safety plan | Explicit separation of server checks vs site FAT/SAT | /solutions/aas-scope-checklist/ |
Core Pillar & Related Briefings#
AAS Foundations Guide All Engineering Insights Agentic AI factory safety: enforcing hard separation from real-time PLCs AI Structured Text (IEC 61131-3): deterministic verification before PLC deployment
Verified Facts and Scope Boundaries#
- Referenced AAS specificationIDTA AAS Specifications v3.2 (IDTA-01001 / IDTA-01002)
The published IDTA AAS specification referenced across our migration and DPP notes.
- Included submodels3
Bundles equipment identification (Nameplate), DualSoft sequence data (SequenceControlData), and 3D geometry metadata (Models3D) in one package.
- Documented concepts83
Public English definitions document every custom sequence concept and ownership qualifier in the reference package.
- Reference identifiers84
Company-maintained public URIs identify the package's concepts, ownership qualifier, and submodel template.
- Package format checkaas-test-engines 1.0.3 (application/aas+zip)
The recorded check covers AASX package structure and AAS metamodel conformance.
- AAS server verificationBaSyx API 3.0: upload / 135 ID lookups
Separate automated runs verified upload and ID lookups on BaSyx 2.0.0-milestone-15. Full API conformity and physical commissioning remain separate.
- PLC engineering-tool importVendor PLC IDE import not executed Not yet checked
Importing a project directly into a specific PLC vendor's engineering IDE has not yet been tested.
- Physical equipment commissioningPhysical commissioning outside this reference scope Not yet checked
Physical factory wiring, commissioning, and safety acceptance are outside this software reference scope.
Scope and Verification FAQ#
Why do Eclipse BaSyx REST API lookups fail with client error responses even when the AASX upload succeeded?
The most frequent cause is using standard Base64 instead of unpadded Base64URL for shell, submodel, or concept-description IDs. Standard Base64 characters (+, /, and trailing =) break REST path segments unless converted to URL-safe unpadded Base64URL.
Can teams reproduce DualSoft's Eclipse BaSyx AASX verification independently?
Yes. DualSoft publishes the reference belt-conveyor .aasx file, the SequenceControlData 1/0 identifier specification, and a reproducible verification script bundle so engineering teams can run schema and local BaSyx REST lookup checks themselves.
How does DualSoft complement open-source Eclipse BaSyx instead of replacing it?
Eclipse BaSyx provides an open-source IEC 63278-1 AAS server and middleware ecosystem. DualSoft complements BaSyx by authoring and validating PLC-linked control models, generating standard AASX packages with SequenceControlData, and connecting equipment diagnostics without locking data inside a proprietary format.
Does passing an Eclipse BaSyx REST API check prove that a live factory PLC is already commissioned?
No. Passing aas-test-engines and BaSyx HTTP lookup checks confirms standard package structure and API interoperability. Vendor PLC IDE import, OT network policies, and physical shop-floor acceptance remain separate project-scoped milestones.
Verified by: DualSoft Engineering — Eclipse BaSyx & IEC 63278-1 REST API Verification Briefing